热门站点| 世界资料网 | 专利资料网 | 世界资料网论坛
收藏本站| 设为首页| 首页

BS EN 12149-1998 卷型墙面材料.甲醛释放和氯乙烯单体、重金属和其它特定元素迁移的测定

作者:标准资料网 时间:2024-05-18 00:46:54  浏览:9404   来源:标准资料网
下载地址: 点击此处下载
【英文标准名称】:Wallcoveringsinrollform-Determinationofmigrationofheavymetalsandcertainotherelements,ofvinylchloridemonomerandofformaldehyderelease
【原文标准名称】:卷型墙面材料.甲醛释放和氯乙烯单体、重金属和其它特定元素迁移的测定
【标准号】:BSEN12149-1998
【标准状态】:现行
【国别】:英国
【发布日期】:1998-02-15
【实施或试行日期】:1998-02-15
【发布单位】:英国标准学会(BSI)
【起草单位】:BSI
【标准类型】:()
【标准水平】:()
【中文主题词】:试样;建筑系统构件;外观检查(试验);有毒物质;氯乙烯;萃取分析法;迁移(化学);单体;重;金属;辊子;甲醛;试样制备;化学分析和试验;含量测定;气相色谱法;墙面饰层
【英文主题词】:
【摘要】:Threemethodstodetermine;thecontentofheavymetalsandotherelementsbysimulatingtheingestionofthematerials,vinylchlorinebyGCusingthe'head-space'methodandformaldehydereleaseusingamodifiedWKImethod.
【中国标准分类号】:Q17
【国际标准分类号】:91_180
【页数】:18P;A4
【正文语种】:英语


下载地址: 点击此处下载
Product Code:SAE J2517
Title:Hybrid III Family Chest Potentiometer Calibration Procedure
Issuing Committee:Dummy Testing And Equipment Committee
Scope:This procedure establishes a recommended practice for establishing the sensitivity of the chest displacement potentiometer assembly used in the Hybrid III family of Anthropomorphic Test Devices (ATDs, or crash dummies). This potentiometer assembly is used in the Hybrid III family to measure the linear displacement of the sternum relative to the spine (referred to as chest compression). An inherent nonlinearity exists in this measurement because a rotary potentiometer is being used to measure a generally linear displacement. As the chest cavity is compressed the potentiometer rotates, however the relationship between the compression and the potentiometer rotation (and voltage output) is nonlinear.Crash testing facilities have in the past used a variety of techniques to calibrate the chest potentiometer, that is to establish a sensitivity value (mm/ (volt/volt) or mm/ (mvolt/volt)). These sensitivity values are used to convert recorded voltage measurements to engineering units, in this case chest compression in mm. Some of these techniques intended to correct for the nonlinearity and others did not. Of those that did correct for the nonlinearity, there was a variation in techniques used. This variation in calibration procedures was in part identified by the SAE Dummy Testing Equipment Committee (DTEC), and led to overall variability in chest compression measurements between laboratories. The intent of this recommended practice is to minimize the variations in chest deflection measurements between crash testing laboratories. Before this procedure was written, a round robin showed variations for the Small Female of 10% among 8 labs for the chest pot sensitivity value. A follow-up round robin of this procedure showed a worst case variation of 2.7% among 10 labs, with a standard deviation of 0.9%. The initial version of J2517 released in May 2000 attempted to fix this problem by recommending a two-point calibration which was not intended to correct for the nonlinearity (which, for example, is as large as 3% for the Small Female but is small near the peak). It also did not require the measurement of a starting position of the potentiometer before each crash test, thus it did not correct for the difference in starting chest geometry between a subject dummy and its design intent. It was intended to be a simple and reproducible calibration procedure which crash test facilities could easily adopt with little or no modifications to their facilities. In practice, most laboratories did not adopt the procedure since it did not correct for the nonlinearities.Recent attempts to reduce dummy-to-dummy and lab-to-lab variations at lower deflection levels (around 25 mm) have renewed interest in adopting a calibration procedure to correct for the nonlinearity of the measurement system. This current revision of this procedure uses a multipoint calibration with a third order regression to correct for the nonlinearities of the system with a standardized method. It requires changes in the calibration method of the transducer, the data collection procedures when used in a dummy, and the processing procedures after test data is collected. Following this standardized methodology will minimize linearity errors as well as lab-to-lab variations.【英文标准名称】:Applicationofstatistics.Inspectionbycountingofnumberofnonconformingitems,inthecaseofanisolatedlot.
【原文标准名称】:统计学和质量.单批不合格品计数检验
【标准号】:NFX06-028-1987
【标准状态】:作废
【国别】:法国
【发布日期】:1987-06-01
【实施或试行日期】:1987-06-05
【发布单位】:法国标准化协会(AFNOR)
【起草单位】:
【标准类型】:()
【标准水平】:()
【中文主题词】:检验;计数;质量管理;统计质量控制;验收检验;验收试验;图解法;检验方法
【英文主题词】:
【摘要】:
【中国标准分类号】:A00
【国际标准分类号】:03_120_30
【页数】:17P;A4
【正文语种】:其他



版权声明:所有资料均为作者提供或网友推荐收集整理而来,仅供爱好者学习和研究使用,版权归原作者所有。
如本站内容有侵犯您的合法权益,请和我们取得联系,我们将立即改正或删除。
京ICP备14017250号-1